Modules

Innovative measurement technology – applied worldwide

Our measurement modules unify extreme reliability, enormous capability and highest precision in one system. Thanks to its innovative technology, high rate of transmission and almost unlimited flexibility, IPETRONIK modules are in continuous operation and provide dependable measurements. That's why many well-known car manufacturers rely on technology and services of IPETRONIK.

CANpressure

Pressure transducer with CAN output for automotive applications

  • Absolute and relative pressure gauge in the range of 1 … 250 bar
  • Internal temperature sensor at gauge point
  • Measurement data output to CAN
  • Galvanic isolation (inputs, CAN, supply, enclosure)
  • Designed for engine compartment applications
  • Toolless module to module connection
  • Ruggedized and compact modules for harsh environments

Learn more

Device
Overload Pressure
3 x full scale / burst pressure > 200 bar
Channel sampling rates
1/ 2/ 5/ 10/ 20/ 50/ 100/ 200/ 500/ 1000/ 2000 Hz
Aggregate sample rate
2 kHz
Oversampling
10 kHz
Voltage supply
6 … 36 VDC
Supply voltage thresholds
Switch-on 6 ±0.3 VDC / Switch-off 6 ±0.3 VDC
Power consumption, typical
0.7 W
Working temperature range
-40 … 125 °C (-40 … 257 °F)
Storage temperature range
-55 … 150 °C (-67 … 302 °F)
IP-Code
Relative IP 52 / absolut IP 65 (ISO 20653 - 2013)
Relative humidity
5 … 95 %
Dimensions
L76 mm x Ø 24 mm (2.99 in x 0.94 in)
Weight
120 g (0.26 lb)
Configuration interface
CAN high speed
Data transfer rate
Software selectable up to 1 Mbit/s (ISO11898-2)
Housing material
Stainless steel 4435
Wrench size
24 mm (0.94 in)
Connecting thread
M 10x1 / M 14x1.5 / G¼ (male / female thread)
Tightening torque
17 … 23 Nm
Thread dimensions M10 (male)
D = 10 mm / L1 = 8.5 mm / L2 = 25.5 mm
Thread dimensions M10 (female)
D = 10 mm / L1 = 9.5 mm / L2 = 26.5 mm
Thread dimensions M14 (male)
D = 14 mm / L1 = 9.5 mm / L2 = 25.5 mm
Thread dimensions M14 (female)
D = 14 mm / L1 = 10.5 mm / L2 = 26.5 mm
Thread dimensions G¼ (male)
D = 13.2 mm / L1 = 9.5 mm / L2 = 25.5 mm
Thread dimensions G¼ (female)
D = 13.2 mm / L1 = 10.5 mm / L2 = 26.5 mm
Galvanic isolation
A/D converter
16 bit / SAR (successive approximation register)
Special functions
Offset adjust, during measurement, multiple groups
Hardware filter (switchable)
1.2 kHz, Butterworth (8-pole)
Hardware filter (switchable)
Accuracy 10 %
Software filter types
Butterworth, Bessel, Elliptic (8-pole)
Software filter (DSP selectable)
6/ 7.5/ 9.96/ 15/ 30/ 39.96/ min
Software filter (DSP selectable)
1/ 1.25/ 1.67/ 2.5/ 5.0/ 6.67/ 10/ 12.5 Hz
Software filter (DSP selectable)
16.67/ 25/ 50/ 66.7/ 100/ 125/ 166.67/ 250/ 500 Hz
Software filter (DSP selectable)
Accuracy 0.05 %
Channel pressure
Pressure range
0 … 250 bar (relative / absolute)
Pressure range
0 … 1/ 2/ 5/ 10/ 20/ 25/ 50/ 100/ 150/ 250/ bar
Accuracy at ambient temperature -40 … 125 °C
0.5 % FS (Full Scale / TEB Total Error Band)
Media temperture range (gas or liquids)
-50 … 150 °C (-40 … 302 °F)
Accuracy of temperarure measurement -40 … 150 °C
±3 K
Accessories
System cable
System cable
System cable
System cable
System cable
System cable
System cable
M-DEF-200.pdf

CO2 sensor

CO2 transmitter for harsh and humid environments

  • Measure carbon dioxide concentration
  • For test benches operating C02 (R744) refrigerant
  • Leakage and safety monitoring
  • Developed for indusrial applications
  • Interchangable probes for easy maintenancenInterchangable probes for simple maintenance
  • Direct connection to SENS modules

Learn more

Device
Voltage supply
11 ... 20 VDC or 18 ... 30 VDC
Power consumption, typical
2.5 W
Working temperature range
-20 … 60 °C (-4 … 140 °F)
Storage temperature range
-30 … 70 °C (-22 … 158 °F)
IP-Code
IP 65 (ISO 20653 - 2013)
Relative humidity
0 … 100 % (non-condensing)
Dimensions
L109 mm x Ø 18 mm (4.29 in x 0.73 in)
Weight
GMM221 180 g (0.40 lb) (w/2m cable)
Housing material
PC Plastik
Measurement CO2
Operating pressure
700 … 1300 hPa
Non-linearitiy
±0.5 % FS (Full Scale)
Typical output temperature dependence
-0.3 % of reading / °C
Typical pressure dependence
+0.15 % of reading / hPa
Sensor Vaisala GMM221
 
Measurement range in %
0 ... 2 / 0 ... 3 / 0 ... 5 / 0 ... 10 / 0 ... 20 %
Accuracy at ambient temperature 25 °C @ 1013 hPa
±1.5 % of range + 2 % of reading (for concentration > 2% FS)
Response time (63%)
20 Sekunden
Sensor Vaisala GMM222
 
Measurement range in ppm
0 ... 2000 / 0 ... 3000 / 0 … 5000 / 0 … 7000 / 0 … 10000 ppm
Accuracy at ambient temperature 25 °C @1013 hPa
±1.5 % of range + 2 % of reading (for concentration > 2% FS)
Response time (63%)
30 seconds
Analog output
 
Analog output resolution
12 bit
Analog output ranges in mA
0 ... 20 / 4 ... 20 mA
External load
max. 200 Ω
Analog output ranges in V
0 ... 1 / 0 ... 2 / 0 ... 2.5 / 0 ... 5 V
External load
min. 1000 Ω

Current clamp

Current clamp for measurement of AC and DC current

  • Current measurement up to 300 A
  • Mobile current measurement according to IEC 1010-1 standard
  • Status LED for supply voltage indication
  • Shock-proof plastic housingmaterial
  • Direct connection to SENS modules

Learn more

Device
Voltage supply
10 … 18 VDC
Power consumption, typical
6 W
Working temperature range
-10 … 50 °C (-14 … 122 °F)
Storage temperature range
-20 … 60 °C (-4 … 140 °F)
IP-Code
IP 40 (ISO 20653 - 2013)
Relative humidity
5 … 80 %
Dimensions
W116 mm x H43 mm x D23 mm (4.57 in x 1.69 in x 0.91 in)
Weight
165 g (0.36 lb)
Housing material
Red reinforced thermoplastic material
Test cable diameter, max.
15 mm x 17 mm (0.59 in x 0.67 in)
Electrical data
Current ranges RMS (type 1)
1 … 100 A
Output ratio (I : U)
100 : 3
Voltage output range
0 … 3 V
Accuracy
2 % (10 … 120 A range)
Current ranges RMS (type 2)
1 … 300 A
Output ratio (I : U)
300 : 1
Voltage output range
0 … 3 V
Accuracy
2 % (30 … 360 A range)
Accuracy @ 400 Hz
3 %
Zero balance
Potentiometer
Frequency range
DC … 1000 Hz
Status LED
Power indication
Minimum external load
30 kΩ
Protection class
III according to IEC 1010-1
Isolation voltage
3 kV @ 50 Hz, 1 min. duration
Accessories
Input cable
Input cable

High Voltage Iso DAQ

4-channel DC high-voltage divider up to 1 kV measuring range

  • Reliable voltage measurement on high-voltage DC systems
  • Electrically isolated high-voltage divider
  • Short-circuit current limitation via HV Current Limiter
  • Measurement data output to CAN
  • For electric and hybrid vehicle applications
  • Approved applications according to CAT I and CAT II
  • Use only together with HV Current Limiter

Learn more

Device
Maximum input protection voltage (channel)
±1000 V (indefinitely)
Channel sampling rates
1/ 2/ 5/ 10/ 50/ 100/ 200/ 500/ 1000/ 2000 Hz
Oversampling
2 kHz
Aggregate sample rate
8 kHz
Voltage supply
9 … 36 VDC
Supply voltage thresholds
Switch-on 9 ±0.3 VDC / Switch-off 6 ±0.3 VDC
Power consumption, typical
7.5 W
Working temperature range
-20 … 70 °C (-4 … 158 °F)
Storage temperature range
-30 … 85 °C (-22 … 185 °F)
IP-Code
IP 54 (ISO 20653 - 2013)
Relative humidity
5 … 95 %
Dimensions
W165 mm x H60 mm x D130 mm (6.50 in x 2.36 in x 5.12 in)
Weight
1370 g (3.02 lb)
Configuration interface
CAN high speed
Data transfer rate
Software selectable up to 1 Mbit/s (ISO11898-2)
Input sockets
4 mm saftey banana plugs
Galvanic isolation
Input ↔ module power supply
±1000 VDC
Input ↔ CAN
±1000 VDC
Input ↔ enclosure
±1000 VDC
Input ↔ input
±1000 VDC
Test voltage
3536 VAC @ 50 Hz (sine wave)
Application according to CAT I
1000 VDC
Application according to CAT II
600 VAC @ 50 … 60 Hz (sine wave)
General channel properties
A/D converter
16 bit / SAR (successive approximation register)
Channel LED
No
Channel impedance
21 MΩ / 100 pF (with HV Current Limiter)
Hardware filter (switchable)
150 Hz, Butterworth (8-pole)
Channel volt
Measurement range SENS
± 1000 V
Accuracy at ambient temperature 25 °C
± 0.05 %
Accessories
System cable
System cable
System cable
System cable
System cable
System cable
System cable
M-DEF-200.pdf

HV Thermocouple

HV sensors for M-THERMO2 HV modules

  • NiCr-Ni type K, classe 1
  • 1 channel sensor (2-pole)
  • 4 channel sensor (8-pole)

Learn more

Device
Diameter
1-channel outer-Ø: 3.6 mm, 2 x 0.2 mm solid
Diameter
4-channel outer-Ø: 6.7 mm, 4 x 0.2 mm solid
Isolation material
Single FEP isolated, (+ green, - white)
Sensor tip
Heatshrink
Length
1, 2, 3, 5 m
Plug
2-pole: CFC.H02.SLK.C52Y1370
Plug
4-pole: CFC.H04.SLK.
Galvanic isolation
Application according to CAT I
850 VDC
Application according to CAT II
500 VDC
Accessories
Datenblatt 1-Kanal-Fühler
Datenblatt 4-Kanal-Fühler

HVshunt

High precision shunt for high-voltage and current measurement

  • For electrical and hybrid vehicle applications
  • High-voltage input up to 850 VDC
  • Current measurement up to 100 A DC via shunt
  • Customer-specific plugs for connection to high-voltage network
  • Operation with Iso Voltage Divider & Iso Clamp Connector
  • Direct connection to SENS modules