Channel volt |
Input voltage |
±1000 V |
Cut-off frequency |
5 MHz |
Input accuracy |
up to 1 kHz ±0.03 % of measured value ±0.02 % measuring range, DC ±0.03 % of measured value, ±0.02 % of measuring range, ±0.04 V, up to 10 kHz ±0.1 % of measuring value, ±0.05% of measuring range, up to 1000 kHz, ±5 % of measured value, ±0.5 % of measuring range, up to 100 kHz ±4 % of measured value, ±0.1 % of measuring range |
Noise |
At 100 KS/s -107 dB, At 15 MS/s -87 dB, At 1MS/s -94 dB, At 10 KS/s -117 dB |
CMR, Typ. (Min.) |
101 dB (88 dB) @ 50 Hz, 75 dB (68 dB) @ 400 Hz |
Gain Drift |
typ. 20 ppm/K (max. 40 ppm/K) |
Offset Drift |
typ. 1.5 mV/K -1 ppm of range/K |
Gain Linearity |
< 0.01 % |
Input Coupling |
DC |
Input Impedance |
10 MΩ || 1 pF |
Hardware filter |
1 MHz, AAF (6th order) |
Channel current |
Current measurement range |
±250 A, ±1000 A |
Maximum withstand peak current |
min. -500 A, max. 500 A, min. -1700 A, max. 2000 A |
Primary / Secondary Ratio |
1 : 1680 |
Input Accuracy (Ip @ 10 Arms) |
DC ±0.1 % of reading ±50 ppm of range ±0.05 A, Up to 20 kHz 70 mdB +/-0.8%, Up to 10kHz 25 mdB +/-0.3%, Up to 200kHz 350 mdB 4% |
Gain drift (current) |
typ. 40ppm/K |
Offset drift |
typ. 200 uA/K |
Linearity error @ 1000 A range |
typ. 50 ppm |
Hysteresis |
typ. 50uA/A |
Flatness DC-50Hz Overall accuracy @25°C |
typ. 5mdB |
Flatness 50-1kHz Overall accuracy @25°C |
typ. 20mdB |
CMRR |
137 dB (450 uA/V) |
General channel properties |
AD converter |
24 bit hybrid ADC |
Device |
Oversampling |
15 MS/s |
Voltage supply |
9 ... 48 VDC |
Power consumption, typical |
13 W (max. 23 W) |
Working temperature range |
-20 ... +70 °C (-4 … +158°F) |
Storage temperature range |
-40 ... 85 °C (-40 ... 185 °F) |
IP-Code |
IP 67 (ISO 20653 - 2013) |
Dimensions |
B245 x H151 x T63 mm (9.65 in x 5.94 in 2.48 in) |
Weight |
4.4 kg (max. 7 kg) / 9.7 lb (max. 15.43 lb) |
Configuration interface |
GbE (XCP, OPC UA) |
Cable diameter |
Nominal DC current 292 A | 95 mm² / 245 A | 70 mm² / 198 A | 50 mm² / 158 A | 35 mm², Rated AC current 206 A | 95 mm² / 173 A | 70 mm² / 140 A | 50 mm² / 111 A / 35 mm² |
High-Voltage Interlock |
YES (chassis covers + cables) |
Accessories |
System cable |
620-688 LOG GB-ETH cable RJ45, HV-PMD-POE-SWITCH-04 (4-Port PoE switch), HV-PMD-PWR-001 (Power Junction), 111540 3m Feature ETH cable RJ45, 620-686 M-LOG-PR08 ETH cable RJ45, 763-101 PWR Weiche-Kabel Büschel HV PMD, 673-100 ETH HV PWR feeder-Cable HV PMD |