M-GATEWAY3

Universal interface module for the M3 DAQ system

The M-GATEWAY3 is the universal interface module for the M3 modular system. The data buses are joined together in one system via the various inputs. The output via the standardized transmission protocol XCPonETH makes the signals available to a wide variety of measurement applications (3rd party systems) without loss. The M-Gateway3 supports the intuitive plug and play-based setup, even for complex measurement tasks.

Special Features

  • Application as CAN-USB or CAN-Ethernet gateway
  • Connection to PC via USB-C (data and power supply)
  • Output via XCPonETH or CAN-FD
  • Online calculations on the module
  • Logging function to record measurement data autonomously
  • Monitoring and control via webinterface and IPEmotion.ME app

Datasheet

Technical Data

Device Service Connections, Interface
Vorlauftemperatur WiFi, Ethernet, USB-C
1,9 m³/h 542

M-GATEWAY3 – Technical data

Download as PDF

Communication
Interfaces CAN HS (ISO 11898-2), Ethernet interface to PC, USB 2.0 ports
Device Service Connections, Interface, Plug, Voltage supply, IP-Code
Medienversorgung (für Betrieb) Ethylenglycolkonzentration
Protocols and traffic OBD
Measurement input DMS Accuracy at ambient temperature -40 ...105 °C
Device
Supported Refrigerants R134a
Interface PCIe Gen4 x4
Arbeitstemperaturbereich L165 mm x B33 mm x H58 mm (L6.50 in x B1.30 in x H2.28 in)
Maximum input protection voltage (channel) Device safety ±60 V (permanent), additional ESD protection
Voltage supply 8 … 18 VDC LIN transceiver through SUB-D connector, 10 … 36 VDC
Working temperature range -20 … 110 °C (-4 … 230 °F)
Storage temperature range -55 … 150 °C (-67 … 302 °F)
IP-Code IP 54 (ISO 20653 - 2013)
Interfaces
Analog input 4 x 0 ... 30 VDC @ 12 bit resolution; 1 % accuracy
Digital I/O 4/2, 8/8
Extender boxes FlexRay, LIN, CAN FD Satellite Interface
Medienversorgung (für Betrieb)
Ethylenglycolkonzentration 30 - 40 %
Vorlauftemperatur WiFi, Ethernet, USB-C
Measurement input DMS
Accuracy at ambient temperature 25 °C ±0.035 % ±3 K in the range 1000 … 1370 °C (1832 … 2498 °F), ±0.035 % in the range -60 ... 1000 °C (-76 ... 1832 °F)
Protocols and traffic
CCP / XCP on CAN Yes
J1939 No
GM-LAN No
FlexRay / XCP on FlexRay Yes
CAN-Traffic Yes
Total error thermocouple type C
Ambient temperature 85 °C @TInput= 0 °C / 1700 °C (±0.325 K / ±0.450 K)
ENOB (Effective Number Of Bits)
ENOB 3.6Vpp sine, measuring range 4Vpp, at 125 Hz Typ. 19.1 bit, with hardware and software filter (250 Hz, Butterworth)
ENOB 1.8Vpp sine, measuring range 2Vpp, at 1 kHz 16.5 bit, without filter (full bandwidth)
Accessories
System cable 620-661 HViso cable STG LEMO 1B7p
Storage capacity
4 ... 64 TB typ. 3 W, max. 50 W
Ben. Volumenstrom bei 35 %
1,9 m³/h 542
Derating (decrease of total output power)
-0.033 W /K at ambient temperature > 45 °C (2 channels) XCPonETH

Personal Consultation

Do you have questions about this product or a special application? Get in touch with our experts!


+49 7221 9922 0