No Message Lost
How data loggers prevent measurement gaps during system start-up
How data loggers prevent measurement gaps during system start-up
When testing vehicles, it is not simply a matter of capturing as much measurement data as possible. It is also crucial that the relevant information is recorded in full and in synchronisation. Particularly when taking measurements on vehicle buses or during vehicle start-up (terminal 15), it is important to capture the very first messages and data on the vehicle buses.
Whilst the system is still booting up, relevant messages may already be transmitted via CAN, LIN or FlexRay. If, for example, the logger is woken up by bus activity, the relevant data may be missing precisely because the measurement system is booting up during this period and is therefore not yet operational.
With No Message Lost (NML), IPETRONIK addresses precisely this start-up phase. Recording begins as early as the first millisecond of the boot process; the measurement data from time zero is buffered separately in the corresponding bus interface and automatically merged with the regular measurement once the measurement system has booted up. The result is a seamless recording with a continuous timeline, including the bus signal that woke the logger up.
Modern vehicles are equipped with numerous control units, sensors and electronic components that continuously exchange information. Vehicle bus systems such as CAN FD, LIN or FlexRay transmit, amongst other things, status information, control commands and measured values between the systems involved via the relevant communication protocols.
During vehicle development and testing, this information is recorded using data loggers. Depending on the measurement task, analogue measured variables, GPS data or other signals may also be included. The stored data subsequently enables developers to analyse a vehicle’s behaviour under real-world conditions and investigate anomalies in greater detail.
Various factors are relevant to the quality of a measurement:
Reliable, comprehensive measurement data acquisition begins at time zero and not only once the measurement system has fully booted up.
Find out more about data loggers and their applications in the automotive sector
No Message Lost begins immediately as the data logger boots up. The recording does not wait for the entire measurement system to have fully booted up, but starts within the first millisecond of the boot process.
The principle at a glance:
The process can be summarised as follows:
Wake-up → Data recording from second zero → regular measurement → complete, continuous recording
This ensures that the start-up phase is fully preserved for subsequent analysis. Critical start-up information, including the triggering bus signal itself, is also part of the recorded measurement.
This principle is particularly relevant for measurements whose start is triggered by a specific event. With Wake-on-CAN, Wake-on-LIN or Wake-on-FlexRay, data may already be generated whilst the system is waking up.
Without data acquisition during the boot phase, the following situation arises:
Event → Data is transmitted → Logger starts → Measurement begins
With ‘No Message Lost’, the start of data acquisition is brought forward:
Event → Logger starts; measurement data is temporarily buffered → Regular measurement takes over
Not every measurement task places the same demands on the first few milliseconds after the system starts up. In the case of a long-term measurement running continuously, the boot phase has a different significance than in a measurement designed to respond specifically to a particular event.
Recording data during start-up is particularly relevant in the following scenarios:
In vehicle testing in particular, it is important to identify correlations, narrow down fault patterns and make the behaviour of components and entire systems traceable. Missing data at the start of a relevant event can make this task unnecessarily difficult.
However, this does not mean that ‘No Message Lost’ is absolutely essential for every measurement and every channel. As the function can be configured on a channel-by-channel basis, it can be applied specifically where completeness is required. The decisive factors are the specific measurement strategy, the behaviour of the logger at system start-up, and whether information required for subsequent analysis is already being generated during this phase.
Find out more about vehicle and test bench testing with IPETRONIK
IPETRONIK integrates ‘No Message Lost’ into various data loggers for vehicle development and testing. This function ensures, particularly in Wake-on-Bus applications, that critical start-up information – including the triggering bus signal – is retained in full.
‘No Message Lost’ is supported by the following IPETRONIK data loggers:
The appropriate data logger configuration depends on the overall measurement task, for example on the required bus interfaces, the number and type of signals, the expected data volume, and the requirements for storage and data transmission. Through channel-by-channel configuration, No Message Lost can also be specifically tailored to those signals where data integrity is essential.
‘No Message Lost’ is a technical feature within a more comprehensive measurement system: the key factor remains the interaction between the data logger, interfaces, software and the respective measurement configuration.
Discover the ARCOS 2 evo with ‘No Message Lost’ and ‘Wake on Bus’
At IPETRONIK, ‘No Message Lost’ refers to a function for data acquisition during system start-up. From the very first millisecond of the boot process, raw data is buffered separately and automatically merged with the regular measurement once the system has fully started up. As the timestamps are generated upon reception, the time series remains continuous. The result is a seamless recording from the very first second.
After being switched on, a data logger requires a certain amount of time before the entire measurement system is fully operational. At the same time, messages may already be being transmitted on the vehicle buses. If recording only begins once the boot process is complete, this early data is not captured by the regular measurement. This can be particularly relevant in ‘Wake-on-Bus’ applications, as bus activity already triggers the logger to start.
Yes. As recording begins within the first millisecond of the boot process, the triggering bus signal is also retained in full. This allows the cause of the wake-up, network start and start-up sequence to be analysed directly.
No. No Message Lost can be configured on a per-channel basis and can be activated specifically for those channels where a complete recording from system start-up is required.
No Message Lost is supported by ETHOS 2, IPE891, ARCOS 2 evo, IPE853 and µCROS SL.
Make an appointment to talk to our experts. You can easily rech us via email or by phone.