HVshunt CCS

Internal temperature monitoring of socket and plug

  • For electrical vehicle applications
  • High-voltage input up to 850 VDC
  • Current measurement up to 300 A DC via current transformer
  • CCS connector with safety lock function
  • Safety shutdown to protection
  • Internal temperature monitoring of socket and plug
  • LED indication about operating status
  • Measurement data output to CAN

Learn more

Device
Voltage supply
10 … 36 VDC
Power consumption, typical
15 W
Working temperature range
-20 … 70 °C (-4 … 158 °F)
Storage temperature range
-30 … 70 °C (-22 … 158 °F)
IP-Schutzart
IP 65 (ISO 20653 - 2013), housing
IP-Schutzart
IP 44 (ISO 20653 - 2013), socket with plug
IP-Schutzart
IP 24 (ISO 20653 - 2013), socket unplugged
Relative humidity
20 … 80 %
Dimensions
L222 mm x B146 mm x H105 mm (8.74 in x 5.75 in x 4.13 in)
Weight
4100 g (9.04 lb)
Configuration interface
CAN high speed
Data transfer rate
Software selectable up to 1 Mbit/s (ISO 11898-2)
Test standards
DIN EN 61851-1
DC charging cables
Phoenix Contact CCS Type 2
Housing material
Polycarbonate (PC)
Status LED
Yes
High-voltage input
Measurement range volt
±850 VDC
Current measurement range
±300 A
Amplitude error for current measurement (10 Hz … 5 kHz)
0.01%
Amplitude error for current measurement (5 kHz … 100 kHz)
1.00%
Amplitude error for current measurement (100 kHz … 1 MHz)
20.0%
Tolerance current transformer at ambient temperature 25 °C
±0.2 %
Linearity current transformer (current measurement)
±0.004 %
Tolerance Iso Voltage Divider at ambient temperature 25 °C
±0.2 %
Tolerance Iso Voltage Divider at ambient temperature -20 ... 70 °C
±0.5 %
Plug temperature control PT1000 (DIN EN 60751)
-50 … 150 °C (-58 … 302°F)
Accessories
System cable