Release Notes __________________________________________________________________________________________________________ Bitte beachten Sie, dass die Release Notes nur in englischer Sprache verfügbar sind. Veuillez faire attention à ce que les Release Notes sont seulement disponible en anglais. Please note that the release notes are only available in english language. __________________________________________________________________________________________________________ Application: IPEmotion Last entry: 28.01.2019 Current version: 2018 R3.1 The distribution of beta versions or release candidates to customers is not enabled without authorization of the management. System requirements: * Screen resolution: min. 1080 x 800 pixel * Processor: min. 2 GHz * RAM: min. 2048 MB * DirectX 9 Recommended system requirements: * Screen resolution: min. 1920 x 1200 pixel * Processor: min. 3 GHz Multi-Core * RAM: min. 6144 MB * Storage medium type: SSD * DirectX 11 Supported platforms: * Microsoft Windows 10 (32 Bit and 64 Bit operating systems) * Microsoft Windows 8.1 (32 Bit and 64 Bit operating systems) * Microsoft Windows 8 (32 Bit and 64 Bit operating systems) * Microsoft Windows 7 (32 Bit and 64 Bit operating systems) The following software will be installed: * Microsoft Visual C++ 2015 Redistributable * Microsoft Visual C++ 2013 Redistributable * Microsoft Visual C++ 2010 Redistributable * IPETRONIK CAN-Server V01.16.02 The following software is required: * Microsoft .NET 4.6.1 Framework PlugIns included in the complete setup: * IPETRONIK LOG V03.63.00 * CAETEC datalog V18.02.00 * IPETRONIK X V02.08.00 * IPETRONIK CAN PlugIn V01.16.01 * Protocols PlugIn V02.02.00 * Video PlugIn V01.03.00 * GPS PlugIn V01.05.00 The IPEmotion program folder must be installed locally. __________________________________________________________________________________________________________ Rights IPEmotion needs administrator rights during installation. Standard user rights are needed for working with IPEmotion. For using IPEmotion a licence-key is required. Please turn to license@ipemotion.com. __________________________________________________________________________________________________________ Content The following points describe changes, restrictions and bugs in the corresponding versions: 2018 R3.1 Import dialog: Bus load calculation for XCPonCAN and CCP protocols FixedBug: Added checkbox in scaling calculator passive sensor tab to specify usage of bipolar excitation for unipolar sensors. (case 42986) FixedBug: Improve Signal/PDU import performance FixedBug: TESTdrive traffic import: correction for CAN FD quickstart traffic FixedBug: AutoSAR importer no longer imports signals belonging to dynamic PDUs in case the plug-in does not support dynamic PDUs. FixedBug: CAN FD traffic: messages with flag bitrate switch (BRS) (case 44421) FixedBug: ZIPRT import with MDF4 files corrected (case 45401) FixedBug: In guided measurement, start and stop time as prefix will be handled correctly for event-controlled channels (case 45445) Known restrictions: Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually In vector graphics, cursor of diagrams (like y-t chart) cannot be displayed because they are drawn directly per GDI Channel names ending with space cause problems in formulas ____________________________________________________________________________________________________________ Windows 7 / How to fix : Windows cannot verify the digital signature for this file The IPETRONIK PTP driver is digital signed with a certificate containing a SHA-2 hashing algorithm. The SHA-2 code signing and verification functionality was not available on windows 7. Microsoft have publish a patch to add this possibility on windows 7 : see: https://technet.microsoft.com/en-us/library/security/3033929 So, if the following error occur by the installation of the X-PI : Windows cannot verify the digital signature for this file Then test if the following security update is installed on the PC : - KB 3035131 - KB 3033929 If there are not installed, please install it manually in the following order : First the KB 3035131 and then the KB 3033929. It can be that the installation of the KB 3035131 say that the patch is already installed(even if it is not occurred by the update list), then install the second patch. And try the installation again. ____________________________________________________________________________________________________________ Windows 7 / How to fix : Windows cannot install the PTP driver silently For a silent installation of the included PTP driver, the following Microsoft Hotfix has to be installed: - KB 2921916 It is important to note, that this hotfix is not distributed automatically by Windows update! Without the hotfix any silent installation might fail on Windows 7. ____________________________________________________________________________________________________________ 2018 R3 Autosar import supports Signal/PDU License key grid: added new columns product (e.g. IPEmotion, Logger) and feature which shows a list of license related features (e.g. Control, Acoustics) View elements can be positioned or docked to (virtual) grid in free mode Yt diagram: date information in axis New script editor with displaying row numbers and syntax highlighting Traffic-To-Signal conversion: KeyValuePairs will be set as user defined parametes Analysis screen can be copied to clipboard as bitmap or vector graphic (definable by an option) PDX import: support for RELATED-DIAG-COMM-REFS PDX import: support for signals defined by TABLE-ROW entries Import of description files: signal filter by INCA experiment (LAB files) KeyValue pairs of channels are stored in IAD file TDM export writes KeyValue pairs as custom properties Log-ph-diagram supports multiple circuits in the online view FIBEX import: support for CAN FD layer Data API: support for ZIPRT and HRD files Analysis: Vector graphics can be used optionally by copy of display elements to clipboard ETHERNET traffic can be exported to PCAP format PDX import: diagnosis address ID as filter column COM functionality: export of screen or visual element to PNG or EMF format COM functionality: ECU firmware synchronisation COM functionality: configuration check and return configuration's status Configurable start index for measurement files in file system FixedBug: Fixed Motorola byte order in Fibex importer 2018 R2.2 FixedBug: Inconsistency for passive sensors (case 40594) FixedBug: Csv filter for DAQ lists (case 42776) FixedBug: Scaling for STG channels corrected (case 42999) FixedBug: Import of array signals corrected (case 43220) FixedBug: GPS displaying corrected (case 42880) FixedBug: ASCII import (case 42787) FixedBug: Analysis cursor (case 42615) 2018 R2.1 FixedBug: Online channel values of connected logger are not displayed correctly in IPEmotion. Broken in 2018 R2. Fixed in 2018 R2.1 2018 R2 Traffic analyzer's accpetance filter can be activated or deactivated in COM FIBEX import supports SOME/IP protocol Support XCP 1.4 in A2L import and export Configuration of persistent data: result at end of measurement can be reused automatically at next measurement start for formulas, classifications and variables Formulas can have a start value Data mining dialog: search in data files for certain condition and display the hits Data mining dialog: sort by file properties Data mining dialog: navigation bar to handle large result lists Data mining: hits will be marked in diagram by click in mining dialog COM functionality for data mining search Analysis elements can be copied optionally to clipboard as vector graphics Custom KeyValue pairs definable per XML file Column display name available Additional map provider with english labeling TESTdrive data import: support for BLF FixedBug: Alphanumerical instrument will now delete immediately on the Delete Visual Element context menu entry in Analysis. FixedBug: Corrected statistic in measurement window when columns not visible (case 40751) FixedBug: Corrected crash after load configuration with empty action button captions (case 40967) FixedBug: Installation in root path actually supported 2018 R1.2 FixedBug: Connect files with certain MDF4 files FixedBug: Autoscale (case 41633) FixedBug: Missing languages (case 41743) 2018 R1 Support for guided measurement (e.g. custom measurement filename, project parameter dialog) Guided measurement: define project paramater which can be used in dialog Data service: configuration and dialog to find channels by different criteria Comparing TEDS sensors in dialog Circular storage group: data is overwritten in a user-defined time Digits after decimal point after detection TESTdrive Traffic import: support for CAN FD frames A2L import supports XCP on CAN FD Configuration of XCP slaves to communicate with logger Diagnostic trouble code (DTC): support for new data type TEDS synchronisation on device level by contex menu TEDS synchronisation on channel level by context menu TESTdrive traffic import: support for CAN FD frames Automatic hardware detection deactivated per default FixedBug: Control objects: always adapt name for internal channels FixedBug: MDF4 export: If TESTdrive data does not contain start date and start time, the absolute time channel will be used. If no valid time information is available, the export will write year 2400 as start time to recognize possible wrong data files. (case 39567) FixedBug: RPC3 Export: export to FLOAT as default (case 38847) 2017 R3.1 FixedBug: GM LAN import corrected (case 37153) FixedBug: Store button could not be removed from acquisition ribbon page FixedBug: Correction for setting free sensor min and max via COM (case 33181) FixedBug: MDF4 export: correction of block size calculation to avoid uncomplete data (case 39295) 2017 R3 AUTOSAR and FIBEX import support Flexray signals with multiplexer Support for user operation plugins (UOP) in data manager Option to reset measurement time in display elements if the measurement mode is set from displaying to storing PDX import can handle eventcontrolled signals Support for BLF traffic import Simple configuration of axis areas for adjustment mode "Joint axis" and "Merge equal axis" Import of TEDS templates and edit of its appropriate parametes TEDS editor: Extended by template Accelerometer and Force Transducer and units (e.g. acceleration, torque, density) IPEspeed dbc with sender DIAdem imort: Time channels in file can be identified by options Output channels can be set by user displays Option to synchronize configuration and description file only by signal name Import start values from DBC ziprt and hrd files can be load per double-click NVH: Correction factor of FFT calculations Displaying behaviour (linear, steps) of an analysis y-t-diagram can now set in its configuration-dialog. Traffic analyzer offline supports filter Font size mode of alphanumerical display: Automatic calculation per channel Optimization of table's font size Sample count classification can show optionally their result in percent ADDRESS_EXTENSION: Support for parameter of CCP protocol FixedBug: 58479 FixedBug: MDF4 export: handles time information of traffic data correctly (case 38683) FixedBug: VTab-Bereiche können bei Kanälen die Ganzzahl-VTabs unterstützen auch mit Fließkommazahlen definiert werden (case 35727) FixedBug: Support for AutoSAR 4.2 Features added to AutoSAR importer (case 37294) 2017 R2 Support for visual element plugins (VEP) online and offline Import of ziprt files Different symbols for DBC, ARXML and FIBEX imported signal measurements Test bench view: Colum orientated display of set channels steps Graphical preview for sequence control Add block directly to sequence control through the context menu Link to block in sequence control through the context menu Precondition block of sequence: Run at the beginning of each loop New tab "Sequence" for blocks Start block of sequence: Run at the beginning of the sequence Optimization of memory usage of operations overall level and order filter Support for LIN traffic data type in traffic analyzer online and traffic exports ASCII and BLF Set sensitivity for active and passive sensors in scaling calculator: CANdb export can handle event signals Mutlipoint scaling must not be strictly monotonic increasing Run script in profil generator PDX multiple ECU Find panel support for grid views Isothermal curves will be shown for a greater temperature range for 1234YF in the log-ph-diagram FixedBug: Correction for ShuntCheck with inverse scaling (case 24159) FixedBug: f(x) button in analysis provides the correct results (case 36392) FixedBug: MDF4 import: Support for rational conversion if its parameters are equal to linear conversion (case 35909) FixedBug: Correction of problems in detailed export (case 35648) FixedBug: Fixed importer problem with multiple DM1 messages without specified sender in J1939 DBC file (case 36035) FixedBug: XCP: Added missing name of transport layer in import properties FixedBug: Results of analysis operations consider "Merge time channels with equal acquisition rate" (case 35616) 2017 R1.2 FixedBug: MDF4 import with rational conversion which matches linear conversion (case 35909) FixedBug: Detection with automatic storage groups (case 30164) FixedBug: f(x) button in analysis provides the correct results (case 36392) 2017 R1.1 FixedBug: Correction for event number of DAQ list (case 35201) FixedBug: Possible error when exporting a large number of merged files (case 35084) 2017 R1 TEDS dialog for reading/writing TEDS blobs UDS acquisition import from PDX ODX validation can be switched off for faster import Read XCP consistency from a2l files Mouse wheel support for diagram axes Filter for traffic analyzer online Traffic analyzer offline with multiple description files Traffic analyzer online and offline: Support for AUTOSAR FlexRay files Import of MDF4 files from ARCOS Import of zipped traffic ASCII files Update bit position: Invalid data points are suppressed Traffic ASCII import with different types (CAN, LIN, FlexRay) Traffic to signal from FlexRay traffic Traffic to signal via COM RPC3 export with float data type Campbell operation: Type of amplitude Additional parameters for operation FFT Order filter operation Displaying range for Campbell operation csv filter in data manager and analysis Redesign of extended measurement window Audio replay improvements Audio replay for Campbell diagram Student license duration extended to 1 year FixedBug: Correction for dbc import with multiple multiplexor (case 33815) FixedBug: XCP service reconnection (case 32974) FixedBug: PDX import optimization (case 12608) FixedBug: PDX import correction concerning CAN IDs (case 33732) FixedBug: Use no value as default value can be set for 'Use as default' (case 32642) FixedBug: MDF4 import correction (case 33224) FixedBug: CSV import: Time channel corrections (case 34566) FixedBug: IPEhub2 data import: find description file with and without prefix (case 33049) FixedBug: Atfx export: do not merge channels in same matrix with unequal value (case 34469) FixedBug: Reporting: No border around the analysis page will be displayed or printed (case 32435) FixedBug: Correction at deleting report pages (case 34150) FixedBug: Reporting pages refresh via COM (case 32436) Known restrictions: In context menu of a datagroup the menu entries to add formulas are no longer available. It is recommended to add formulas by creating formula operations on data manager page instead. Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Channel namens ending with space cause problems in formulas 2016 R3.1 FixedBug: MDF4 export corrected FixedBug: MDF4 import corrected FixedBug: Automatically close sync dialog Known restrictions: Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Channel namens ending with space cause problems in formulas 2016 R3 Info at language change Possibility to clear output window ppm as sub unit of percentage Auto return FlexNet borrow licenses at new borrow Profile generator with reference values from file Check channel steps for profile generator New formula operations IS_NOVALUE, RADIUS and ANGLE Additional features for profile diagram Traffic analyzer supporting AUTOSAR Redesign of alphanumeric display Connection of auto splitted acquisition data files Option to connect data files Rotation of angle axis of polar diagram in multi sync mode Identification of signals with same time channel Traffic to signal from AUTOSAR and FIBEX FixedBug: Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface FixedBug: IPEspeed.dbc update (case 31455) FixedBug: Additional warnings inactive by default if expert settings are activated Known restrictions: Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Channel namens ending with space cause problems in formulas 2016 R2.1 FixedBug: Only pure event signals in CANdb are set to event-contolled by default (case 32092) Known restrictions: For exporting special characters to a pdf file a suitable font has to be set manually The provider for the map background has ceased its service on short notice. The map instrument will display error messages behind the data tracks. Ribbon customization file of older versions can cause problems Channel namens ending with space cause problems in formulas 2016 R2 Support of XCP 1.2 features DAQ list syncronisation improved Support for DAQ lists > 1ms Duplicate signal name message improved Save message send rate from CANdb Event signal support in imports Consider order of jobs defined in idf Scaling parameters from plugin data TEDS sensor detection with preferred unit Additinal refrigerant fluids Profile generator Redesign of LED and switch Display unit in classifications Additional tree and grid columns in data manager and analysis Replay mode for traffic analyzer Support CANdb xml files at traffic to signal conversion Index numbering at traffic to signal conversion adapted Pattern for default names of analysis operations Video properties in data manager Data reduction for video data Copy to file and paste from file for report pages Progress dialog at switching report pages Campbell operation optimized x64 data api IronPython 2.7.5 Known restrictions: Ribbon customization file of older versions can cause problems Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface For exporting special characters to a pdf file a suitable font has to be set manually The provider for the map background has ceased its service on short notice. The map instrument will display error messages behind the data tracks. Channel namens ending with space cause problems in formulas 2016 R1.1 FixedBug: Script operations with no source channels will not be calculated correctly at loading configuration on analysis tab Known restrictions: Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Channel namens ending with space cause problems in formulas 2016 R1 FIBEX import for CAN Read sender in FIBEX/AUTOSAR import Manual size configuration for dynamic XCP daq lists Acceptance filter configuration dialog AUTOSAR support for FlexRay parameter import CAN ID edit in import dialog Optional column 'Port' in channel usage dialog Additional climate operators FlexRay traffic in traffic analyzer Additional Campbell operation and extension for FFT operation FlexRay traffic in data manager Matrix support for iad import and export User defined key value columns in all areas Support for G.I.N. microphone data Support for single values in data exports ATFX/PAK export extended Text channels in MDF4 export Campbell diagram Support of Windows 10 IPEcan OEM setup as optional feature in complete setup Demo plugin code locked Setup time reduced FixedBug: csv printing uses the list column separator from the control panel by default FixedBug: Color source channel is selected at re-entering the selection dialog (case 26429) FixedBug: The print dialog is not available in touch mode. Quick printing has to be used instead. Known restrictions: Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Script operations with no source channels will not be calculated correctly at loading configuration on analysis tab Channel namens ending with space cause problems in formulas 2015 R3.3 FixedBug: Alphanumeric instrument considers existing entries of verbal table for calulating font size, even if scaling of channel is set to Factor/Offset FixedBug: Display of merged logger data files can be inconsistent, if data files are not loaded in chronological order Known restrictions: Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Channel namens ending with space cause problems in formulas 2015 R3.2 FixedBug: MDF4 import with duplicate channel names in a channel group (case 28324) FixedBug: Channel scaling in MDF4 could be wrong (case 28324) FixedBug: No padding with first or last valid value when trying to merge channels with equal acquisition rate (case 27662) FixedBug: Closing storage files with invalid channels correctly FixedBug: y axes disappeared when selecting channel in acquisition window FixedBug: IPEhub2 export to IPEhub2 device does not require valid export directory (case 27586) Known restrictions: Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface Channel namens ending with space cause problems in formulas 2015 R3.1 FixedBug: Export of operation results via COM FixedBug: CAN-ID values in channel selection dialog were always in decimal format (case 27565) Known restrictions: Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface For exporting special characters to a pdf file a suitable font has to be set manually Ribbon customization file of older versions can cause problems Channel namens ending with space cause problems in formulas 2015 R3 Possibility to add sensor database entries manually Mark TEDS channel after manual changes TEDS error messages improved Additional climate operator h_ps in the climate package Analysis operations for 2D classifications Initialize classification anlysis operations with source channel properties Classification table in the anaylsis Polar diagram in the anaylsis Syncronisation of video data with other data in post process Progress bar for long time analysis operations Optional layout for each report page New field command for accessing single values Ribbon buttons for myIPE FixedBug: Between installation of .NET framework 4.5.1 and IPEmotion a system reboot is required FixedBug: Opening a report or changing to report page containing a polar chart will take a long time FixedBug: Mixed mode for CAN FD/CAN for CAN FD traffic is not supported yet FixedBug: The default value of exporting the view configuration into the app configuration has been changed to 'yes' FixedBug: Display name column in channel grid was missing Known restrictions: Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface Channel namens ending with space cause problems in formulas 2015 R2.1 FixedBug: CANdb export via COM consumed memory FixedBug: Detailed export did not always work correctly (case 26096) FixedBug: Map: Color source channel selection via check box (case 26429) Known restrictions: Between installation of .NET framework 4.5.1 and IPEmotion a system reboot is required Ribbon customization file of older versions can cause problems For exporting special characters to a pdf file a suitable font has to be set manually Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface 2015 R2 New app export features Support for touch mode and high resolution mode in dialogs CAN FD support for AUTOSAR import Optional second column for csv files at signal import Handling of H264 data improved Automatic display range adaption for imported floating point signals Option for always splitting array signals at import Button edit for path selection of storage groups Traffic generator instrument Map view redesign Filtering for dlc and data length column of traffic analyzer Data type column for traffic analyzer Font for traffic analyzer adapted Reset button also resets axis scalings to original scalings Import of traffic asc files Csv import: Empty cells at the end are no longer interpreted as no values Analysis operation 'Statistics' Analysis operation 'Segment by time' Analysis operation 'Find time from condition' Analysis operation 'Find index from condition' Support for single value channels in formulas Only compatible channels addable in analysis instruments Data objects for classification and FFT Grid views for analysis operations Possibility to add analysis formulas to pool New analysis instrument for 3D models Transparency for background of instruments in reporting Support of analysis edition in user button demo Plugin designer update FixedBug: Parent menu of empty sub menus is not grayed out FixedBug: Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface FixedBug: Report view of traffic analyzer ignores filter and sorting FixedBug: Fix issue with negative NMEA coordinates in map (case 19479) FixedBug: Pasting DAQ lists corrected Known restrictions: Between installation of .NET framework 4.5.1 and IPEmotion a system reboot is required The print dialog is not available in touch mode. Quick printing has to be used instead. Mixed mode for CAN FD/CAN for CAN FD traffic is not supported yet For exporting special characters to a pdf file a suitable font has to be set manually Ribbon customization file of older versions can cause problems 2015 R1.3 FixedBug: Displaying of video files via Video Extender system caused exceptions FixedBug: Exporting of connected loaded iads files in DIAdem TDM caused an exception (case 25313) Known restrictions: Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface Between installation of .NET framework 4.5.1 and IPEmotion a system reboot is required Ribbon customization file of older versions can cause problems Using ',' as decimal separator with culture 'en-US' causes problems at hardware detection The print dialog is not available in touch mode. Quick printing has to be used instead. 2015 R1.2 FixedBug: Correction for detection with complete configuration (case 24277) FixedBug: Cut and paste for channel links did not work correctly (case 18051) FixedBug: Sensor min/max calculation in grid corrected FixedBug: Time offset in motion data corrected FixedBug: Offline formulas did not work FixedBug: Tolerance for TEDS sensor supply range added Known restrictions: Between installation of .NET framework 4.5.1 and IPEmotion a system reboot is required Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface The print dialog is not available in touch mode. Quick printing has to be used instead. Ribbon customization file of older versions can cause problems Using ',' as decimal separator with culture 'en-US' causes problems at hardware detection 2015 R1.1 FixedBug: IPEmotion could open without appearing in the task bar (case 23725) FixedBug: Displaying of statistic frames in traffic analyzer Known restrictions: Using ',' as decimal separator with culture 'en-US' causes problems at hardware detection Report view of traffic analyzer ignores filter and sorting Ribbon customization file of older versions can cause problems Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface Between installation of .NET framework 4.5.1 and IPEmotion a system reboot is required 2015 R1 64 bit version available Touch mode System status window as floating window with showing the source object at double click Acquisition configuration and view configuration in user administration Rescue edition Refprop path configuration via option dialog Map provider selection Support for CAN FD Filter operations Info message at detection with no active plugin Hiding inactive channels in online view Analysis operation sequences Traffic analyzer in the analysis Classification diagram in the analysis Table instrument in the analysis Index column in extended measurement window FixedBug: Grid columns for sensor min / sensor max use best matching sensor range Known restrictions: Using ',' as decimal separator with culture 'en-US' causes problems at hardware detection Report view of traffic analyzer ignores filter and sorting Ribbon customization file of older versions can cause problems Between installation of .NET framework 4.5.1 and IPEmotion a system reboot is required Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface 2014 R3.1 FixedBug: Scripting for standard and anylsis edition did not work (case 22349) FixedBug: Internal scripting for runtine version did not work Known restrictions: Using ',' as decimal separator with culture 'en-US' causes problems at hardware detection Hotfix installation without administrative rights or without deactivated UAC might cause problems concerning the COM interface 2014 R3 App export: Include limit configuration in IAW, info about limitations Printing and export for dock panels New control for CAN-ID´s Reporting duplicate channel names in the configuration check Reference namens in configuration check New unit 'Flux density' New unit 'Bridge sensitivity' 'Do not show again' for messages with 'Yes' and 'No' Loading configurations of newer versions Automatic array split in import Function group sorting for A2L import GM-LAN import with channel selection DTC´s for PDX import Grid columns for user defined key values Multipoint scaling in sensor database Message comment in CANdb import Storage groups: Automatic channel administration, script after file conversion Reference names for internal channels Online table with output functionallity Extended export dialog Zipped blocks for MDF4 export Use native channel data types at ATF export Use native channel data types at ATF export x-y-diagram for channels with two dimensions Alphanumerical displays in the analysis Thicker lines in the legend Reporting via COM PDF export via COM Timeout for floating licenses increased Known restrictions: Using ',' as decimal separator with culture 'en-US' causes problems at hardware detection 2014 R2.1 FixedBug: Loading files with inconsistent no value corrected (case 21518) FixedBug: Bit coding of FlexRay signals corrected (case 20671) FixedBug: Syncronisation with XCP+ improved (case 21477) FixedBug: Video export corrected (case 20860) FixedBug: Problem with TESTdrive event files with many included groups fixed (case 21616) FixedBug: No traffic generator node in editions less than professional FixedBug: Correction for dbc import in chinese version (case 20994) FixedBug: PDX import corrected (case 21209) FixedBug: No channel deactivation after App export FixedBug: Prevent reboot during setup FixedBug: Pasting sequence controls with block links corrected Known restrictions: Using ',' as decimal separator with culture 'en-US' causes problems at hardware detection 2014 R2 New features in app export PDX import for diagnostics Search for Seed & Key file Support for AUTOSAR 4.x Object based scripts in context menu for signal page Protocol selection for dbc import (J1939) Obsolete parameters in IDF import Option for switching off J1939 protocol in dbc import Traffic simulation New features for sequence control New features for traffic analyzer Support for double clicking status bar messages for diagrams Editing properties and values of acqusition data in data manager MDF 4.1 Default naming of acquisition data file exports improved Different data types for TDM export Support MDF format in TESTdrive import Using XSLX for Excel data exchange Copy elements from online view to analysis Line type of analysis charts configurable Function for resetting position of measuring cursors Action buttons in analysis VTAB support in CSV/XLS export The load measurement button of the storage group dock panel does not reset the data pool anymore Color management in maps improved Scaling of absolute time axes improved Legend in report improved Ring buffer for raw data backup directory FixedBug: Updating the IPEmotion Excel AddIn is handled properly by stand alone and IPEmotion setup in versions starting with 2014 R2. Otherwise it is required that the IPEmotion Excel AddIn 2014 R1(.x) must be uninstalled manually before installing newer versions. FixedBug: Save app export folder during session (case 19090) FixedBug: Import of predefined DAQ lists corrected FixedBug: Start bit in UDS import properties FixedBug: Wrong channel links after paste behind (case 18813) FixedBug: Adaption of reference names after A2L syncronisation (case 18969) FixedBug: Correction for pasting CCP/XCP (case 18712) FixedBug: Caption for FIBEX selection dialogs (case 17187) FixedBug: Sensor range of scaling channels corrected FixedBug: Problem at FAMOS export fixed (case 19292) FixedBug: ATFX export improvements (case 15584) FixedBug: Error mesage at TESTdrive import improved (case 19292) FixedBug: Problem with parallel installation fixed (case 19113) FixedBug: Problem with dock panel at start corrected (case 18321) FixedBug: Scrolling in dock panel in right corner FixedBug: Data size adaption at switching data types (case 19491) 2014 R1.4 FixedBug: AppExport: CAN-1 does not need to be configured anymore Known restrictions: The Progress bar is not moving during loading of large files Problem with parallel installation fixed 2014 R1.3 FixedBug: FlexNet license borrowing corrected (case 20180) FixedBug: Correction for time syncronization with own clock channels (case 18432) 2014 R1.2 FixedBug: Correction to prevent corrupt CloudSettings.xml causing crash at start of IPEmotion FixedBug: Correction for sequence control hold handling Known restrictions: The Progress bar is not moving during loading of large files Depends on the TEDS configuration the SX-STG TEDS sensor has been detected successfully but the values are not displayed in 2014 R1.1 Support hotfix setup. The default behaviour can be modified by the command line parameter "HOTFIX". language packs: fr-FR, ja-JP, ko-KR, zh-CHS, zh-CHT, ru-RU FixedBug: Please consider (If a new version of the IPEmotion Excel AddIn(Standalone Setup file)is installed,the user will be asked wether to uninstall the last version or not. Uninstall is recommended) FixedBug: Importing from a CSV file took a long time (case 18052) FixedBug: Change the channel position while scrolling mode FixedBug: The name of IPETRONIK LOG PlugIn in the setup window is now corrected FixedBug: The exported IAD file from a video (Motion type) was too large FixedBug: Under Time diff column from Traffic Analyzer the time diff values were always zero in log mode FixedBug: Cut and paste did not work for channel type MOTION Known restrictions: The Progress bar is not moving during loading of large files Depends on the TEDS configuration the SX-STG TEDS sensor has been detected successfully but the values are not displayed in 2014 R1 extended support of video acquisition IPEmotion App export directly from suitable nodes map data administration graphical DAQ fill level overview support for characteristics signal based FIBEX-FlexRay import TEDS data storage in sensor database writable part for sensor database default baud rates for CAN and LIN DAQ list sample rate added to import properties number of polling lists between 0 and 4 (depending on the plugin support) reference support in storage groups Traffic window in online view table instrument in online view Excel AddIn for IPEmotion acquisition data Excel xlsx export order of import/export file formats adapted extended wav export replay of audio data via speakers in analysis COM interface extensions version tag for user button xml update installation automatic value adaptions including status message for depencies configuration options single help text for radio group items optimized assembly pre-compilation during setup to reduce setup time possibility to remove licenses from license list about dialog via template changable licensing of COM interface optional plugin licensing FixedBug: The HTML export placed overlapping objects incorrectly FixedBug: Uninstalling current version deletes files in the application and user data directory although further versions are installed FixedBug: The functions and updating of some customized buttons in ribbon is not working correctly if are not placed on the default page FixedBug: By using separate coordinate systems for the y-t chart in Analysis area the time axis is not scaled to the earliest time FixedBug: Audio export does not show error message if no audio channel is exported FixedBug: Adjustment of the time axis from the y-t chart in Analysis area after changing the time channel format is not scaled correctly FixedBug: The cursors are not movable after deleting the channels in Analysis area FixedBug: Some COM-function are just usable after initialisation of View page FixedBug: Correction for TEDS unit (case 17261) FixedBug: Corrections concerning IPEcloud settings FixedBug: Pasting CAN interfaces with protocols (case 18630) FixedBug: Signal count check in UDS acquisition import FixedBug: Traffic to signal conversation duration (case 18529) FixedBug: Dependency check for local project parameters (case 18484) FixedBug: Problem at starting IPEmotion without any visible dock panel (case 18321) FixedBug: Automatic color assignment (case 18259) FixedBug: App export corrected (case 16153) Known restrictions: The Progress bar is not moving during loading of large files Depends on the TEDS configuration the SX-STG TEDS sensor has been detected successfully but the values are not displayed in 2013.2.1 Language packs: fr-FR, it-IT, ja-JP, ko-KR, zh-CHS, zh-CHT FixedBug: There were different size of the exported MDF4 files (case 17842) FixedBug: A wrong assignment caused by the cut and paste behind of channels with the same name (case 17872) FixedBug: IPEmotion crashed (Analysis Edition) if the element log ph is added FixedBug: IPEmotion konnte nicht reagieren während Seitenwechsel in der Analyse tab (case 17585) FixedBug: Opening of scaling calculator after changing the signal values ??caused IPEmotion crash FixedBug: Opening from scaling calculator of a particular configuration causes IPEmotion crash FixedBug: CAN-Server installation reactivated FixedBug: DAQ type were not correctly inserted by copy and paste FixedBug: The formatting of the Release notice has been corrected FixedBug: Revised relative time axis has had odd divisions FixedBug: (Only German version) the text size of the button "Per CSV auswählen" on the import dialog was not due to the button size FixedBug: An exception came when the index was out of the range in Scaling calculator FixedBug: Starting IPEmotion as Administrator with Windows 8.1 as operating system is not possible FixedBug: The administrator(OR the user) was not able to start IPEmotion, if the user(OR the Adminstartor) had made ??some changes in options FixedBug: Pre trigger handling corrected (case 17327) Known restrictions: By using separate coordinate systems for the y-t chart in Analysis area the time axis is not scaled to the earliest time Depends on the TEDS configuration the SX-STG TEDS sensor has been detected successfully but the values are not displayed in Adjustment of the time axis from the y-t chart in Analysis area after changing the time channel format is not scaled correctly The cursors are not movable after deleting the channels in Analysis area The Progress bar is not moving during loading of large files Uninstalling current version deletes files in the application and user data directory although further versions are installed Some COM-function are just usable after initialisation of View page 2013.2 IPEcloud: automatic creation and deletion of network drive Dock windows (messages, status, ...) can be docked outside Option dialog can be sized IPEmotion App export New hotkeys added Driverless dongles Import – MDF4 Import – WAV audio files Confirm pop-up windows of limit channels Carriage return for formulas Usage of the exact unit of TEDS sensors Unit conversion button in scaling calculator New unit kWh CANdb xml import Distinction between VTAB and VTAB range in scaling calculator Support for syncronization of array signals Selection count info in selection dialog Memory optimization for VTAB´s Apply ICP sensor mode from sensor database Offset for active and passive sensors Automatic sensor range adaption for channels with resolution Switch between decimal and hexadecimal number in import settings Warning for dynamic XCP daq lists Drop down for storage rate of storage group Channel selection for signal generator source y axis on both diagram sides Configurable ring buffer for xy diagram Storage rate in iad impacts file size CE block Open measurement files on double click Delete particular file in data manager Group export of traffic data New properties for data groups Time range for zoom can be set Copy values from measurement window to clipboard Optimal range for x axes Coloring option for map tracks Syncronized displaying of audio data Text marker values can be edited in the analysis Configuration dialog for field commands Multiple time axes in analysis Field commands for min, max, mean Measurement window in reports Format parameter for field commands use of extended address space Script error messages improved Script import shows all supported formats Data import and export settings setable via COM settings FixedBug: Syncronization of channel color in cursor mode corrected (case 16552) FixedBug: Depends on the TEDS configuration the SX-STG TEDS sensor has been detected successfully but the values are not displayed in FixedBug: VTAB channels can be set by using spin buttons now (case 16236) FixedBug: Invalid invisible local project parameters are visible for correction (case 16922) FixedBug: Import syncronization with VTAB´s no longer gives wrong feedback (case 16901) FixedBug: Reference of J1939 signals corrected FixedBug: Plug in configurations with systems included are not checked at loading anymore FixedBug: Environment export corrected FixedBug: Missing source formats for file function generator added FixedBug: FFT´s without source channels could cause wrong online data displaying FixedBug: MDF3 export concerning max length of group text corrected (case 16539) FixedBug: Some configurations from older versions could not be loaded (case 15979) FixedBug: Missing grid columns for source type and bus type added FixedBug: y min and y max of analysis charts were sometimes not configurable FixedBug: Out of memory error at syncronization fixed (case 14553) FixedBug: Name of project parameters are no longer reseted after 'Change into' FixedBug: Error when leaving job selection dialog without selection fixed (case 15600) FixedBug: Csv import error at duplicate channel names corrected (case 15610) Known restrictions: By using separate coordinate systems for the y-t chart in Analysis area the time axis is not scaled to the earliest time Audio export does not show error message if no audio channel is exported Adjustment of the time axis from the y-t chart in Analysis area after changing the time channel format is not scaled correctly The cursors are not movable after deleting the channels in Analysis area The Progress bar is not moving during loading of large files Uninstalling current version deletes files in the application and user data directory although further versions are installed The HTML export placed overlapping objects incorrectly The functions and updating of some customized buttons in ribbon is not working correctly if are not placed on the default page Some COM-function are just usable after initialisation of View page Starting IPEmotion as Administrator with Windows 8.1 as operating system is not possible Pre trigger handling corrected copy DAQ type at paste Corrections concerning IPEcloud settings CAN-Server installation reactivated V03.01.02 Fixed bug: The loan period of the borrowed license was not displayed correctly Fixed bug: The absolute time information in the exported file with FAMOS filetype was not available V03.01.01 Supported Languages :French, Italian, Korean, Japanese, Chinese (simplified & traditional), Russian Fixed bug: Click on the function button f(x) in the Analysis area has caused IPEmotion crash Fixed bug: Results of the checking of Imported ATFX have not met the specification Fixed bug: Default width of the measurement window was inappropriate Fixed bug: The font size was not retained in the external display Fixed bug: The change of the font size was not directly included in the external dispaly Fixed bug: Resize of the Property area in Data manager caused an exception Fixed bug: External display does not work correctly with fixed / automatic font size adjustment Fixed bug: The displayed exported video has not synchronous with the original file Fixed bug: Importing of signals from a LIN connector does not work correctly Fixed bug: Clicking on the f(x) in Analysis area after loading a video data caused an exception Fixed bug: Clicking on raw files during measuring process caused an exception Fixed bug: Adding new signals from original dbc with J1939 protocol to the new saved configuration was not possible Fixed bug: Deleted DM1 signals were still selected after opening the import dialog again Fixed bug: Channels with same name were assigned to the same SPN although ther ID were differnet Fixed bug: Status, FMI and OC signals had been removed automatically Fixed bug: After a successful Login as Administration the Logout button was not present Fixed bug: Status signals of the DM1 message was not correctly exported Fixed bug: Time Channels in CSV file were not correctly recognized by their unit V03.01.00 Significantly faster program start Extended pcense interface to change/switch between different pcense types Server pcensing with Borrow & Floating functions New interface for the support file generation Checking IPEmotion and the PlugIns release Versions of IWF files Jumping from a warning message directly to the object causing the warning Removing the IPEmotion splash screen PC system monitoring includes RawDataBack folder New font sizes S, M, L, XL for messages and display objects New tab sheet combinig all VIEW settings CSV Import with preview function and save all import settings in a template Graphtec data logger import (GL800-, GL 900-, GL7000-Series) Export - Video Formats (AVI with MJPEG and h264 Codec) DBC, A2L, Autosar import with CSV reference file for channel pst Add channel names to a pull down menu in the SIGNALS work space The device & channel pst (tree overview) is indicating the channel count of the active channels System check includes Seed&Key for A2L files Full channel reference: PlugIn / System / Device / Channel Scapng calculator for any channel Formula editor is indicating syntax errors Data storage - enabled when channels are included inthe store group Automatic scrol function when moving channels in the store group channel pst Onpne chart analysis in the Yt-chart Yt-chart with wiper display function Fixed font size for the alphanumerical display and scroll functions Bulk download of map tiles Action button with background color Display up to one VIEW page on a second monitor Export supports channels with TEXT format Diadem DAT import - automatic chronolgical sorting Video Export from data file with multiple vidoe channels - AVI file for each video channel created MDF4 Export includes full channel reference Cursor statistics with sample count indication Channel highpghting through cursor statistics window and diagram legend Free cursor position between data points Defining specific cursor positions through the context menu Automatic apgnment of the x-axis (graphics) is possible if yt charts is located exactly on top of each other Report cover sheet Known restrictions: Pause button from the Spectrum element on the external display is not working correctly External display works only partially with fixed/automatic font size First displaying of the window "Options" takes some second under certain conditions High-resolution video data (> 720 x 576) with audio are not displayed correctly Deinstallation of the IPEmotion version is not able to delete the folder under "Start menu -> All Programs" V03.00.03 Fixed bug in AutoSAR importer that prevented detection of signals Fixed bug with corrupt project parameter by using function change into Fixed loading of raw data with text channel without values Fixed update problem of the DAQ-fill level V03.00.02 IPEmotion installation checked the correct .net Framework 4 version (Full Profile is required) Translation errors were fixed Error at moving ECU-Signals to another DAQ-List was fixed Error after starting IPEmotion (language Italian) was fixed Fixed synchronization bug of XCP protocol when polling DAQ list is used Fixed export of Diadem measurement files Fixed problem with pasting special formulas Error of asking to save changes after using export to mcf was fixed If IPEmotion uses default channel names for devices, channels are avaiable in a storage group and the devices were switched by mapping function than the channels with the same name are deleted from the storage group Error of loading zip files with prefix was fixed V03.00.01 Fixed problem with page initialization when ribbon is customized Fixed file name display in file save dialog in case the file filter specifies a fixed file name IPEmotion opens the file dialog with last used path Error at installation of Dongle driver was fixed Displaying text in wrong font colour was fixed Channel selection: More than one channel can be selected Picture added to help windows of Shunt Check V03.00.00 All IPEmotion Editions offer a wider range of functions Online / Offline OpenStreetMaps position display / load guidance track Online Classification calculations with data presentation in Histogram and Tables Sample count / Time at level / From to count /Level crossing /Transition matrix / Rainflow Sample count compound /Time at level compound Sharing IWF project files is easy as external files like pictures are included The ribbon offers now customizing options and larger icons across the whole GUI Software activation can be done Online Default directories are changed to: C:\Users\Public\Documents\IPETRONIK\... UTC time zone switching function to analyze data files recorded in different time zones Imports: CSV and GPX import format Exports: AVI files and MDF 4 Shunt Check for X-PlugIn (Sx-STG & Mx SENS Modules) CANdb import / export for channels with more 32 characters CANdb import indicates DAQ List Overflow A2L import is e.g. supporting XCPonEthernet on CAN connectors Control Module: Router Channels to send data from any input to any output Oscilloscope Diagram - settings for the block factor from 10 ...100% Compute more statistics between cursors in the offline analysis Create reports now with data tables Scripting is supporting Iron Python V02.07.03 A much smaller license stick / dongle is available Known restrictions: Flexray Extender can only be deleted with Clear The Clean Button icon is not updated when the button is added to ribbon Some display elements with channel cannot be pasted xy chart cannot be displayed the cursor if the current value has no value Deleting of a channel with absolute time format may cause changing time format to relative Import progress window of logger data isn't mudal Some verifications of inputs can be skipped by right mouse click V02.00.06 - skin change problem after import fixed V02.00.05 - Refresh problem is fixed - Error at grid view of module grids is fixed - Possible dead lock with progress dialog is fixed - Error at control elements with invalid channel links is fixed - Correction at loading plug in options - Free memory after using import dialogs - Error at reading scope data is fixed - Error at remote kernel is fixed - Fixed A2L synchronization problem with old IPEmotion configurations V02.00.04 - Possibility to start systems without init after detect under certain conditions - Error at pasting storage groups with markers corrected - Handling for ecu type 0xFF corrected - Correction for value with unit columns of plug ins - Problem with channel references corrected - Always close raw data files at leaving the storage mode - Free memory after report creation - PasteBehind index correction - correction for VTAB comparison V02.00.03 - Error at importing of AutoSAR is fixed - Error at importing of TESTdrive files with prefix is fixed - Error at importing od iad files with same value of min and max is fixed V02.00.02 - COM-Interface for IPEmotion options - Error at importing of AutoSAR is fixed - Error at loading of project-specific data is fixed - Error at loading of configuration of Reporting is fixed V02.00.01 - Updated links to the new IPEmotion home page - Reporting-page takes the current zoom from the Analysis-page - Error at displaying singals at the yt-chart is fixed - Error at scrolling the data of the data manager is fixed - Error at exporting of measurement data by time range is fixed Known restrictions: - Relative links on the welcome-page are usable with IE 7.0 (or similar internet browsers) or higher V02.00.00 - New skin in Windows 8 style - AUTOSAR-import via ARXML-Dateien - Sequence control for automating test bench sequences - Global and local project settings - Edit functionality in reports - Limit value infringement for ranges - Check configuration - Cross refrence for channels to get an overview where a channel is used - Integrated help window in the option dialog - Copy in and paste from file - Copy single display element to clipboard - VTAB-support in scaling calculator - New IPEmotion Light-Edition for max. 64 channels Known restrictions: - Configuration files projectPar.xml and projectData.xml have been replaced by globalPar.xml and globalData.xml - 16bit color depth can cause displaying errors - Deactivated handling of router and router element status via COM interface - Right mouse button to exit a field with invalid entry - Overlapping objects in html export are displayed next to each other - Rich text draws texts out of frame - Multiline at text box behaves incorrectly V01.09.01 - FlexRay signals impported via FIBEX are dactivated by default - Problem when deactivating many channels fixed - Error at using measurement cursor fixed if window is deactivated - Updating problem at changing setup entries fixed - Updating problem at displaying channels fixed if a channel is not available in view - Error at changing entry fields for function generators fixed with tab - Font size for displaying channel values is adapted to element size - Error at moving channels into another visual element fixed - Consideration of BitLength if DataType is not defined - Error at loading a file, which has been selected within signal generator, fixed - Error at defining properties of signal generator fixed with Enter - IPELayouts with new IPETRONIK logo V01.09.00 - Offline calculations (Generate new calculations in the IPEmotion analysis) - TEDS (Transducer Electronic Data Sheet) sensor support - Enhanced reporting functions (e.g. support of field commands, reports includes the project parameters) - Supporting XCPonFlexray protocol including Fibex-import - A2L-import of UDS (Unified Diagnostic Services) measurement protocol - A2L-import supports VTAB (Verbal Table) - Import of TDM data format - Configurable data import and export (e.g. country specific formats) - Formular parser dialog with integrated help window and import of formulars out of a formula pool - Markers to set tags with time stamp and free text input during the acquisition - Full screen mode to remove title bar, ribbon and tree view from IPEmotion screen - Direct opening of zipped measurement files (e.g. TESTdrive) - Compare of IPEmotion configuration files and displaying the differences - Limit value infringement with pop-up messages - Offline log p-h diagram and new enthalpy calculations (optional) - IPEmotion licensing via FlexNet-serve Known restrictions: - The ZIP import does not support splitted archives - The ZIP import cannot be combined with the "Connect data" option - The TDM import does not support NoValues (except those of the double data type) - Report templates with the file extension .repx are stored with the file extension .irl - The reporting page does not support the display of cursors - The status variable can possibly be set to a value greater than 1 - Numbers with more than 256 digits are not supported within the formula editor - After defining a formula at the analysis page, the loaded channels are displayed - Reducing the width of the signal table at the signal page may cause an error - Changing between diagrams in the analysis tab may cause the cursor to jump to the acquisition start or a second cursor can be displayed - Changing between plugins in the signals tab during a running display/acquisition may cause an error V01.08.03 - Bug concerning possible additional data at the end of an aquisition fixed Known restrictions: - The channel names of the systems are often not printed out when printing in a non-fixed layout - The 'Add channels'-feature available from the context menu in the Channels section is available although no visual element is selected - When the Pages section in the Analysis tab is resized, context-based functionalities are sometimes not available - When the righthand cursor overlaps the lefthand cursor, they are no longer indistinguishable - While exporting traffic-data in MDF4-Format the data could be corrupted - During the playback of a measurement with video element and an absolute time channel, there is a time-shift between the video and the measurement - 'RTF-Export' exports the page without a proper format - While undoing/redoing an operation, the warning icon might not be displayed - The modification of some 'Limit value'-properties (like Message type, comparison operator) cannot be undone - In the data management tab, when all channels are selected using the SHIFT-KEY, only the same type of channels will be selected - The COM-Interface oparates properly only when the UAC is set to 'Never notify' during the installation - The 'Delete'-Icon in the Quick Access Toolbar displays an odd behavior when the focus is on the 'Loaded measurement files' section V01.08.02 - Possibility to set hex mode as default for integer edit - Bit count in FlexRay signal import corrected Known restrictions: - The channel names of the systems are often not printed out when printing in a non-fixed layout - The 'Add channels'-feature available from the context menu in the Channels section is available although no visual element is selected - When the Pages section in the Analysis tab is resized, context-based functionalities are sometimes not available - When the righthand cursor overlaps the lefthand cursor, they are no longer indistinguishable - While exporting traffic-data in MDF4-Format the data could be corrupted - During the playback of a measurement with video element and an absolute time channel, there is a time-shift between the video and the measurement - 'RTF-Export' exports the page without a proper format - While undoing/redoing an operation, the warning icon might not be displayed - The modification of some 'Limit value'-properties (like Message type, comparison operator) cannot be undone - In the data management tab, when all channels are selected using the SHIFT-KEY, only the same type of channels will be selected - The COM-Interface oparates properly only when the UAC is set to 'Never notify' during the installation - The 'Delete'-Icon in the Quick Access Toolbar displays an odd behavior when the focus is on the 'Loaded measurement files' section V01.08.01 - Support for chinese, french, japanese and korean language - Show physical value in test acquisition of scaling calculator - Bugfix concerning limit configuration - Deinstallation now only deletes empty directories Known restrictions: - The channel names of the systems are often not printed out when printing in a non-fixed layout - The 'Add channels'-feature available from the context menu in the Channels section is available although no visual element is selected - When the Pages section in the Analysis tab is resized, context-based functionalities are sometimes not available - When the righthand cursor overlaps the lefthand cursor, they are no longer indistinguishable - While exporting traffic-data in MDF4-Format the data could be corrupted - During the playback of a measurement with video element and an absolute time channel, there is a time-shift between the video and the measurement - 'RTF-Export' exports the page without a proper format - While undoing/redoing an operation, the warning icon might not be displayed - The modification of some 'Limit value'-properties (like Message type, comparison operator) cannot be undone - In the data management tab, when all channels are selected using the SHIFT-KEY, only the same type of channels will be selected - The COM-Interface oparates properly only when the UAC is set to 'Never notify' during the installation - The 'Delete'-Icon in the Quick Access Toolbar displays an odd behavior when the focus is on the 'Loaded measurement files' section V01.08.00 - Control (optional) - Online log p-h diagram and enthalpy calculation (optional) - Online output window for all plugins (Hyperterminal functionality) - Reporting: Creation of own layouts - Multistate display in digital instruments incl. configurable background images (e.g. valve configuration) - New import of description files, e.g. DAQ lists to be selected with A2L - Automatic saving of configuration to avoid data loss - Analysis edition for evaluation of data Known restrictions: - The channel names of the systems are often not printed out when printing in a non-fixed layout - The 'Add channels'-feature available from the context menu in the Channels section is available although no visual element is selected - When the Pages section in the Analysis tab is resized, context-based functionalities are sometimes not available - When the righthand cursor overlaps the lefthand cursor, they are no longer indistinguishable - While exporting traffic-data in MDF4-Format the data could be corrupted - During the playback of a measurement with video element and an absolute time channel, there is a time-shift between the video and the measurement - 'RTF-Export' exports the page without a proper format - While undoing/redoing an operation, the warning icon might not be displayed - The modification of some 'Limit value'-properties (like Message type, comparison operator) cannot be undone - In the data management tab, when all channels are selected using the SHIFT-KEY, only the same type of channels will be selected - The COM-Interface oparates properly only when the UAC is set to 'Never notify' during the installation - The 'Delete'-Icon in the Quick Access Toolbar displays an odd behavior when the focus is on the 'Loaded measurement files' section V01.07.01 - french, italian, chinese, japanese and korean version included Known restrictions: - Loaded measurements with the same name are unable to be exported in another measurement format - In the entry mode STG in the scaling calculator the Sensor mode is current available - Best fit of columns according to content is adapted by headline - Error and Information should be possibly displayed during the import of description file - Values of Yt-axles by multiple choice of channel are possibly unable to be configured - Zoom step by mouse control is lower than by keyboard control - Channels addressing by export of FAMOS-measurements without channels is not accurate - Executing of programs when overriding limit values is possibly able to crash IPEmotion - If the multipoint scaling has been used the test acquisition takes the scaled values - The tables of linearization are not supported during the import of description files V01.07.00 - Acquisition data export into new data formats: KML, BLF, Famos, MDF4 - Import of video data of all IPETRONIK data loggers - Configurable background images for all screen pages - Start scripts and applications with one button on each page - Load DBC files after traffic acquisitions - New CANdb import - Edit already imported parameters of description files Known restrictions: - Loaded measurements with the same name are unable to be exported in another measurement format - In the entry mode STG in the scaling calculator the Sensor mode is current available - Best fit of columns according to content is adapted by headline - Error and Information should be possibly displayed during the import of description file - Values of Yt-axles by multiple choice of channel are possibly unable to be configured - Zoom step by mouse control is lower than by keyboard control - Channels addressing by export of FAMOS-measurements without channels is not accurate - Executing of programs when overriding limit values is possibly able to crash IPEmotion - If the multipoint scaling has been used the test acquisition takes the scaled values - The tables of linearization are not supported during the import of description files V01.06.05 - korean translations added V01.06.04 - Missing translations added Known restrictions: - Channels can only be added separate to a xy-diagram - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion - Multiline formulas cannot be handled via copy & paste - CCP: Signal-Array - signals are doubly present - No request for saving project data by execute button "automatic gernaeration" - No single select after all select (Ctrl + A) at channel selection - No verification of names of channels in the Storage group under certain conditions - No Grid update after incorrect input of Formulas - Button "1 Cursor" and "2 Cursor" for video scrolling has no function - Minimizing of IPEmotion reduce the left area at Analysis V01.06.03 - Italian, chinese, japanese and korean version Known restrictions: - Channels can only be added separate to a xy-diagram - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion - Multiline formulas cannot be handled via copy & paste - CCP: Signal-Array - signals are doubly present - No request for saving project data by execute button "automatic gernaeration" - No single select after all select (Ctrl + A) at channel selection - No verification of names of channels in the Storage group under certain conditions - No Grid update after incorrect input of Formulas - Button "1 Cursor" and "2 Cursor" for video scrolling has no function - Minimizing of IPEmotion reduce the left area at Analysis V01.06.02 Bugfix concerning wrong scaling at a2l import fixed Known restrictions: - Channels can only be added separate to a xy-diagram - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion - Multiline formulas cannot be handled via copy & paste V01.06.01 - Analysis diagrams keep ranges after changes Known restrictions: - Channels can only be added separate to a xy-diagram - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion - Multiline formulas cannot be handled via copy & paste V01.06.00 - FFT-diagram online- Automatic XCP-Service - Muli-licensing via USB-dongle incl. download- and upload functionalitiy - Static measurement window for displaying the actual cursor value for each channel Known restrictions: - Channels can only be added separate to a xy-diagram- Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion V01.05.03 - italian, chinese, japanese and korean versions Known restrictions: - XY-diagram: No multiple channel selection, no cursor management and no syncronization with other diagrams - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion - Synchronisation of imported array signals is currently not supported - When synchronizing an imported CANdb not all CAD-ids may be synchronized - 64 bit signals are imported correctly but always displayed in double format - CSV-filter: Changing the drive via keyboard, the directory in the dialog will not be refreshed - Multiline formulas cannot be handled via copy & paste V01.05.02 - error at storage in other formats than IPEmotion format fixed - error displaying wrong online data at inactive nodes fixed - loading IPEmotion acquisition data files with video channels corrected - possible exception at software start fixed - error at scaling from scaling calculator fixed - possible timestamp problem at long time acquisition fixed - diagnostic files (idf) with multiple ecus Known restrictions: - XY-diagram: No multiple channel selection, no cursor management and no syncronization with other diagrams - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion - Synchronisation of imported array signals is currently not supported - When synchronizing an imported CANdb not all CAD-ids may be synchronized - 64 bit signals are imported correcty but always displayed in double format - CSV-filter: Changing the drive via keyboard, the directory in the dialog will not be refreshed - Multiline formulas cannot be handled via copy & paste V01.05.01 - diagnostic files (idf) with multiple ecus Known restrictions: - XY-diagram: No multiple channel selection, no cursor management and no syncronization with other diagrams - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion - Synchronisation of imported array signals is currently not supported - When synchronizing an imported CANdb not all CAD-ids may be synchronized - 64 bit signals are imported correcty but always displayed in double format - CSV-filter: Changing the drive via keyboard, the directory in the dialog will not be refreshed - Multiline formulas cannot be handled via copy & paste V01.05.00 - XY-diagram online and offline - Osziloscope diagram online - Licensing via USB-dongle - Installation for "all users" possible Known restrictions: - XY-diagram: No multiple channel selection, no cursor management and no syncronization with other diagrams - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion - Synchronisation of imported array signals is currently not supported - When synchronizing an imported CANdb not all CAD-ids may be synchronized - 64 bit signals are imported correcty but always displayed in double format - CSV-filter: Changing the drive via keyboard, the directory in the dialog will not be refreshed - Multiline formulas cannot be handled via copy & paste V01.04.00 - Extension of cut/copy/paste functionality - New analysis functions (measurement cursor, replay, synchronized diagrams) - Video display (online and offline) - New grey skin - Possibility to define scaling of signals in signal database - Sensor database is now accessible from signal grid - Sensor favorites can be defined for quick access to your favorite sensors - Possibility to define your own ribbon buttons - Creation and configuration of limit values via automation interface is now supported - Synchronisation of signals with sensor database Known restrictions: - No persistant unit configuration - Synchronisation of imported array signals is currently not supported - Using "," as decimal seperator with en_US language settings can lead to errors in Mircosoft XML-parser and therby in IPEmotion V01.03.00 - UserSettings are reset at language change - - channel index in source column added - HUD for analysis diagramms - instruments with output functionality - quick starter for start accelaration - cut/copy/paste functionality (step 1) - light blue skin - expert mode for detailed configuration possibilities - COM interface in basic edition available - possibility to change components of type system and device - reset value for output channels of limits Known restrictions: - No persistant unit configuration - Via the automation interface it is not possible to create channel links (e.g. adding a channel to a display on an IPETRONIK logger) - Automated configuration of IPETRONIK loggers is limited (regards statistics, XCP service, diagnostics...) - Copying the properties of an IPETRONIK logger on another logger does not copy the data transfer settings completely - Copying of imported channels ist not supported completely - Synchronisation of imported array signals is currently not supported V01.02.00 Known restrictions: - No cut, copy, paste functionality - No persistant unit configuration - Creation of limit values via automation interface ist not supported. During macro recording, this operation is ignored. V01.01.01 New version of the formula calculator Error at trigger conditions fixed Known restrictions: - No persistant context menus (right mouse click) - No cut, copy, paste functionality - No undo / redo functionality - Data export only with separate time channel for each signal channel - Signal library mode is not supported completely - No persistant unit configuration - No CANdb import of 64-bit signals - Error message when using formulas with CANdb signals in charts, functionality is not limited V01.01.00 Known restrictions - No persistant context menus (right mouse click) - No cut, copy, paste functionality - No undo / redo functionality - Data export only with separate time channel for each signal channel - Signal library mode is not supported completely - No persistant unit configuration - No CANdb import of 64-bit signals - Error message when using formulas with CANdb signals in charts, functionality is not limited V01.00.00 Known restrictions - No persistant context menus (right mouse click) - No cut, copy, paste functionality - No undo / redo functionality - Data export only with separate time channel for each signal channel - Signal library mode is not supported completely - No persistant unit configuration